Operator Console for Page/Private System
Control-room handset console for paging over the page/private system
9 models · compare
The control-room and loudspeaker end of a SMART PA system. Operator consoles for MCS-II, MCS-III and page/private systems, external and rack amplifiers, and indoor and outdoor speakers.
Control-room handset console for paging over the page/private system
Desktop console with zone and all-call keys for the MCS-II
Digital console for MCS-III with caller ID and 50-station phonebook
Desktop paging console with built-in amplifier for page/private systems
100 W external amplifier that adds horns to a SMART PA phone
Second 100 W external amplifier model for extra loudspeaker horns
250 W rack amplifier module on 100 V lines for MCS-III, ISAS
Re-entrant ABS loudspeaker horn for outdoor plant paging
Differences first: interface, power, protection and output, then installation. Each model page has the full specification table.
3 of up to 4 operator consoles, amplifiers & loudspeakers selected.
Comparing OC-DTHS-I, OC-DTHS-II, OC-DTHS-III
| Specification | OC-DTHS-I Operator Console for Page/Private System | OC-DTHS-II Operator Console for MCS-II | OC-DTHS-III Operator Console for MCS-III |
|---|---|---|---|
| Interfacediffers | Stand-alone | Analogue | Analogue |
| Power supplydiffers | 220 V / 110 V AC | 220 V AC / 110 V AC (switchable) | 220 V AC / 110 V AC |
| Power consumptiondiffers | < 15 W | < 15 W | < 5 W |
| UPS loaddiffers | Not specified | 20 VA (RMS), peak 45 VA | 20 VA (RMS), peak 25 VA |
| Cablediffers | Not specified | 0.5 mm 2-core twisted telephone cable from MCS; 1.5 sq mm 3-core power cable | 0.5 mm 2-pair telephone cable from MCS; 1.5 sq mm 3-core power cable |
| Microphonediffers | Noise cancelling dynamic | Noise cancelling dynamic | Noise cancelling |
| Moisture resistance | 0 to 95% humidity with PCB conformal coated | 0 to 95% humidity with PCB conformal coated | 0 to 95% humidity with PCB conformal coated |
| Environment | Indoor | Indoor | Indoor |
| Temperature | 0 to +60 °C | 0 to +60 °C | 0 to +60 °C |
| Dust resistance | Fully weatherproof enclosure | Fully weatherproof enclosure | Not specified |
| Insulation | Not specified | 600 V for 3 min between power source & telephone line | 600 V for 3 min between power source & telephone line |
| Amplifier | 10 W (RMS) | 10 W (RMS) | Not specified |
| Housing | 16-gauge powder-coated steel body | 16-gauge powder-coated steel body | Not specified |