☎ +91 98226 95746WhatsApp11:00 – 19:00 IST
Request a quote
SMARTMCS-II

Industrial PA System, Distributed Amplifier

Non-blocking PA exchange, 24 to 112 ports, amplifier in every phone

112 ports max12 zones2000 m loop220/110 V AC
Datasheet · PDF 1.2 MB

1 / 2

Ask an engineer about MCS-II on WhatsApp →

Environment
Indoor · Outdoor
Interface
Analogue

Ideal for

  • Cement plants
  • Steel plants
  • Power generation facilities
  • Fertilizer plants
  • Large and medium-scale industrial units

What it does

Plant-wide paging without a central amplifier rack. The 100% non-blocking MCS-II master control station links SMART PA telephones, each with its own 30 W amplifier, for individual, zone and all-call paging plus private intercom. Telephone-grade cable runs up to 2000 m to each location, and up to 4 EPABX trunk lines patch in outside calls.

  1. 01

    24 ports, expandable to 112 in multiples of 16

  2. 02

    Up to 12 zones of up to 12 PA telephones; all-call up to 64 ports

  3. 03

    Loops up to 2000 m on 0.5 mm 2-core twisted telephone cable

  4. 04

    Amplifier in each PA telephone: no high-power amplifier, no 19 in rack

  5. 05

    Up to 4 operator consoles and up to 4 EPABX trunk lines

  6. 06

    Expands without hardware change

Specifications

Electrical · 6
Power supply220 V / 110 V AC
PA telephone line40 V
Power consumption< 100 W
Insulation600 V for 3 min between power source & telephone line
Ringer voltage50 V AC (100 V PP)
UPS loadMCS 24 ports 50 VA (RMS) / peak 90 VA; MCS 112 ports 130 VA (RMS) / peak 220 VA; PA telephone 30 VA / peak 55 VA; operator console 20 VA / peak 45 VA
Acoustic · 1
LoudspeakersLSOD outdoor horn, LSIN indoor box speaker
Mechanical · 5
Dimensions320 × 380 × 200 mm
Weight8.5 kg
Housing16-gauge powder-coated steel body
MountingVertical wall / desktop
Junction boxJB-II – 16-gauge steel, integrated canopy, single PCB with surge protection, wall mount
Environmental · 2
Moisture resistance0 to 95% humidity with PCB conformal coated
Temperature0 to +60 °C
Connectivity · 5
Loop lengthLong loop supported (up to 2000 m)
EPABX patchingUp to 4 trunk lines of plant EPABX to extension tie lines of MCS
DiallingTone
Cabling0.5 mm 2-core twisted telephone cable MCS to each location; 1.5 sq mm 3-core power cable; 0.75 mm 2-core flexible cable to loudspeaker horns
Field unitsSMART PA telephones WMHS-II, WMHF-II
Operation · 5
Architecture100% non-blocking TDM/PCM
PortsMinimum 24; expandable up to 112 PA telephone ports; installation in multiples of 16
All callUp to 64 PA telephone ports
ZonesUp to 12 predefined zones; up to 12 PA telephones per zone
Operator consolesUp to 4 (DTHS-II)

Compare with similar models

Differences first: interface, power, protection and output, then installation. Full specifications are in each model's table.

Comparison of MCS-II with similar models. Rows that differ come first; “Not specified” means the datasheet does not list it.
SpecificationMCS-II
Industrial PA System, Distributed Amplifier
MCS-III
Industrial PA System, Central Amplifier
MINI MCS-II
Compact Industrial PA System
WMHS-IIAD
Addressable PA Telephone
InterfacediffersAnalogueAnalogueAnalogueStand-alone
Power supplydiffers220 V / 110 V AC220/110 V AC220 V / 110 V AC220 V AC / 110 V AC (switchable)
Power consumptiondiffers< 100 W< 100 W< 35 W< 35 W
UPS loaddiffersMCS 24 ports 50 VA (RMS) / peak 90 VA; MCS 112 ports 130 VA (RMS) / peak 220 VA; PA telephone 30 VA / peak 55 VA; operator console 20 VA / peak 45 VAMCS 24 ports 160 VA (RMS) / peak 240 VA; operator console 20 VA / peak 25 VA; EXA PA 250 320 VA / peak 450 VANot specified50 VA (RMS), peak 90 VA
Insulationdiffers600 V for 3 min between power source & telephone line600 V for 3 min between power source & telephone lineNot specified600 V for 3 min between power source & signal line
EnvironmentdiffersIndoor, OutdoorIndoor, OutdoorIndoorIndoor, Outdoor
MountingdiffersVertical wall / desktopNot specifiedNot specifiedVertical wall / panel
Cablingdiffers0.5 mm 2-core twisted telephone cable MCS to each location; 1.5 sq mm 3-core power cable; 0.75 mm 2-core flexible cable to loudspeaker horns0.5 mm 1-pair telephone cable MCS to each location; 0.5 mm 2-pair cable to operator console; 0.75 mm 2-core flexible cable from amplifiers to hornsNot specifiedNot specified
PortsdiffersMinimum 24; expandable up to 112 PA telephone ports; installation in multiples of 16Minimum 24 industrial telephone ports, expandable up to 112; 16-line telephone cardsMaximum 32Not specified
Dimensionsdiffers320 × 380 × 200 mmRack mountedNot specified360 × 160 × 180 mm
Weightdiffers8.5 kg8.5 kgNot specified5 kg
Housingdiffers16-gauge powder-coated steel body16-gauge powder-coated steel body16-gauge powder-coated steel body16 SWG powder-coated steel body

Part of a system

Plant PA system

Paging and private talk across a whole plant, in two architectures. MCS-II puts a 30 W amplifier in every PA telephone and needs no amplifier rack; MCS-III keeps line-powered phones in the field and drives 100 V loudspeaker lines from central 250 W amplifiers.

How the system works

Downloads

PDFSMART MCS-II datasheet1.2 MB

Questions

How far can a PA telephone be from the MCS-II?

Up to 2000 m, on 0.5 mm 2-core twisted telephone cable.

How many phones does it take?

A minimum of 24 ports, expandable up to 112 PA telephone ports, installed in multiples of 16.

Do I need a 19 inch amplifier rack?

No. Each SMART PA telephone carries its own amplifier, so there are no high-power amplifiers or relay-based loudspeaker controllers.

Need MCS-II for a project?

Tell us the quantity, the plant and the timeline. We reply with a quotation.

Go to quote list
WhatsApp